46

Issue 1 CRCS R6.0 April 1999

Appendix A: Modem Pooling

Figure 39.

Add Modem-Pool Screen

The following fields may be assigned for the Combined Modem Pooling solution:

n

Speed: Enter one, two, or three communication speeds in bits per second
of the conversion resources in the group. Speeds include LOW, 0 to 300
blind sampled, 300, 1200, 2400, 4800, 9600, or 19200. Separate entries
with more than one speed with slashes (for example, 300/1200/2400,
which indicates a maximum of three running speeds). For CRCS connec-
tivity, enter 9600. Default is LOW/300/1200.

n

Duplex: Enter full or half to indicate the duplex mode of the conversion
resources in the group. For CRCS connectivity, enter full. Default is full.

n

Synchronization: Enter sync or async to indicate the synchronization
mode of the conversion resources in the group. For CRCS connectivity,
enter asynch. Default is async.