Parameter table A - Boiler Operation

Table 1D_This table lists SMART SYSTEM control module parameters and where to access them for boiler operation
ONLY

1

Service

(continued)

Menu

Sub

Item

Description

See

Page

User Access

Installer Access

Display Modify Display Modify

A

1

User Code

17

Yes

Yes

Yes

Yes

2

Date and Time

17

Yes

Yes

Yes

Yes

3

Software Version (Software Ver)

17

Yes

No

Yes

Yes

4

Temperature Units (Temp Units)

17

Yes

Yes

Yes

Yes

5

SH Night Setback Offset (SH NSB Temp)

17

Yes

Yes

Yes

Yes

6

SH Night Setback Times (SH NSB Time)

17

Yes

Yes

Yes

Yes

7

DHW Night Setback Offset (DHW NSB Temp)

17

Yes

Yes

Yes

Yes

8

DHW Night Setback Times (DHW NSB Time)

17

Yes

Yes

Yes

Yes

B

1

SH Setpoint (SH Setpoint)

17

Yes

Yes

Yes

Yes

2

SH Minimum Setpoint (SH Min Setpt)

17

No

No

Yes

Yes

3

SH Maximum Setpoint (SH Max Setpt)

18

No

No

Yes

Yes

4

SH Offset

18

No

No

Yes

Yes

5

SH Differential (SH Differentl)

18

No

No

Yes

Yes

6

Manual Reset High Limit (Man Res Hi Lim)

18

Yes

Yes

Yes

Yes

7

Auto Reset High Limit (Aut Res Hi Lim)

18

Yes

Yes

Yes

Yes

C

1

Hours Running SH (Hours Run SH)

18

No

No

Yes

Yes

2

Hours Running DHW (Hours Run DHW)

18

No

No

Yes

Yes

3

Ignition Attempts (Ign Attempts)

18

No

No

Yes

Yes

4

Last 10 Lockouts

18

No

No

Yes

Yes

D

1

Clear Error Log (Clr Error Log)

18

No

No

Yes

Yes

2

Service Mode Delay (Service Delay)

18

No

No

Yes

Yes

3

Display Timeout (Display Time)

18

No

No

Yes

Yes

4

Bypass Valve Time (Bypass V Time)

18

No

No

Yes

Yes

5

Freeze Protection Pump On (Freeze Pump)

19

No

No

Yes

Yes

6

Freeze Protection Burner On (Freeze Burn)

19

No

No

Yes

Yes

7

Freeze Protection Differential (Freeze Differ)

19

No

No

Yes

Yes

E

1

Tank Setpoint

19

Yes

Yes

Yes

Yes

2

DHW Boiler Setpoint (DHW Blr Setp)

19

Yes

Yes

Yes

Yes

3

SH/DHW Switching Time (SH/DHW Switch)

19

Yes

Yes

Yes

Yes

4

DHW/SH Switching Time (DHW/SH Switch)

19

Yes

Yes

Yes

Yes

5

DHW Tank Differential (DHW Tank Diff)

19

No

No

Yes

Yes

F

1

Minimum Outdoor Temperature (Min Air Temp)

20

No

No

Yes

Yes

2

Maximum Outdoor Temperature (Max Air Temp)

20

No

No

Yes

Yes

3

Maximum SH Setpoint (Max SH Setpt)

20

No

No

Yes

Yes

4

Minimum SH Setpoint (Min SH Setpt)

20

No

No

Yes

Yes

5

Outdoor Shutdown Setpoint (Outdoor Shtdn)

20

Yes

Yes

Yes

Yes

6

Outdoor Shutdown Differential (Shutdown Diff)

21

Yes

Yes

Yes

Yes

7

Shift Reset Curve (Shift Reset)

21

No

No

Yes

Yes

8

Boost Temperature (Boost Temp)

21

Yes

Yes

Yes

Yes

9

Boost Time

21

Yes

Yes

Yes

Yes