Parameter table A - Boiler Operation

(continued)

Table 1D_(continued from previous page) This table lists SMART SYSTEM control module parameters and where to
access them for boiler operation ONLY

Menu Sub

Item

Description

See

Page

User Access

Installer Access

Display Modify Display Modify

G

1

Anti-cycle Time (Anti Cycl Tm)

21

No

No

Yes

Yes

2

Anti-cycle Override Differential (Override Diff)

21

No

No

Yes

Yes

3

Minimum On/Off Delay Stages 1, 3 (On/off Delay)

21

Yes

Yes

Yes

Yes

4

Next On Delay

21

Yes

Yes

Yes

Yes

H

1

SH Controlling Sensor (SH Cnt Sensor)

22

No

No

Yes

Yes

2

Enable Input (Active / Inactive)

22

No

No

Yes

Yes

3

BMS Input (Active / Inactive)

22

No

No

Yes

Yes

4

Cascade (Active / Inactive)

22

No

No

Yes

Yes

5

Sequencer

22

No

No

Yes

Yes

6

ModBus (Active / Inactive)

22

No

No

Yes

Yes

7

ModBus Timeout (ModBus Time)

22

No

No

Yes

Yes

I

1

Boiler Address (Blr Adress)

23

No

No

Yes

Yes

2

Maximum Cascade Setpoint (Max Casc Stpt)

23

Yes

Yes

Yes

Yes

3

Cascade Offset (Cas Offset)

23

No

No

Yes

Yes

4

Cascade Differential (Cas Different)

23

No

No

Yes

Yes

J

1

BMS Type

23

No

No

Yes

Yes

2

Voltage at Minimum (V at Min)

23

No

No

Yes

Yes

3

Voltage at Maximum (V at Max)

23

No

No

Yes

Yes

4

Minimum Power (Min Power)

23

No

No

Yes

Yes

5

Maximum Power (Max Power)

23

No

No

Yes

Yes

6

Minimum Setpoint (Min Setpoint)

23

No

No

Yes

Yes

7

Maximum Setpoint (Max Setpoint)

24

No

No

Yes

Yes

8

Voltage to Start CFH (V at Start)

24

No

No

Yes

Yes

9

Voltage Differential Stop CFH (V Diff Stop)

24

No

No

Yes

Yes

K

1

System Pump Delay (Sys Pump Dlay)

24

No

No

Yes

Yes

2

SH Pump Delay (SH Pump Delay)

24

No

No

Yes

Yes

3

DHW Pump Delay (DHW Pump Dlay)

24

No

No

Yes

Yes

4

System Pump Mode (Sys Pump Mode)

24

No

No

Yes

Yes

L

1

Service Interval Time (months) (Srv Int Time)

24

No

No

Yes

Yes

2

Service Interval Run (Srv Int Run)

24

No

No

Yes

Yes

3

Service Interval Operation (hours) (Srv Int Op)

24

No

No

Yes

Yes

4

Reset Service

24

No

No

Yes

Yes

5

Accept Personality Plug (Accept PPlug)

24

No

No

Yes

Yes

ANTI-

CY

CLING

CONTR

OL

MODES

CASCADE

BMS

PUMPS

SER

VICE

NO

TIFICA

TION

Copper-fin II/IIE Boiler and Water Heater

Service Manual