OUTPUT CABLES

Select the output cable size based upon the following
chart.

Cable sizes for Combined Length of Electrode and
Work Cable (Copper) 75° rated:

Duty

Length Up

61-76m

Cycle

Current

61m (200 ft.)

(200-250 ft.)

100%

250

1/0

1/0

60%

300

1/0

2/0

QUICK DISCONNECT PLUGS (K852-7)

A quick disconnect system is used for the welding
cable connections. The welding plug included with the
machine is designed to accept a welding cable size of
1/0 to 2/0.

1. Remove 1 inch (25mm) of welding cable insulation.

2. Slide rubber boot on to the cable end. The boot

end may be trimmed to match the cable diameter.
Soap or other lubricant will help to slide the boot
over the cable.

3. Slide the copper tube into the brass plug.

4. Insert the cable into the copper tube.

5. Tighten set screw to collapse copper tube. The

screw must apply pressure against welding cable.
The top of the set screw will be well below the sur-
face of the brass plug after tightening.

6. Slide the rubber boot over the brass plug. The rub-

ber boot must be positioned to completely cover all
electrical surfaces after the plug is locked into the
receptacle.

25 mm

1 in.

WELDING CABLE

BOOT

TRIM

SET SCREW

BRASS PLUG

COPPER TUBE