V300-PRO

TROUBLESHOOTING & REPAIR

TEST PROCEDURE

1. Turn main power OFF.

2. Perform Input Filter Capacitor Discharge proce-

dure detailed in Maintenance section.

3. Detach the following PC boards so you can gain

access to and have ample room to perform the
tests: (Do not disconnect from wiring harness.)

Control Board

Protection Board

Power Board

NOTE: Do not disconnect any wires. The machine
must be functional to perform tests.

4. Arrange the PC boards and wiring so you can easi-

ly perform the tests.

NOTE: Do not allow live connections to touch each
other.

5. Turn main power ON.

6. Move the Output Terminal Switch S4 to the ON posi-

tion (closed).