And table f.3 . if any test fails, Troubleshooting & repair, Switch board test (cont.) – Lincoln Electric INVERTEC V300-PRO SVM105-B User Manual

Page 58

Advertising
background image

V300-PRO

TROUBLESHOOTING & REPAIR

F-28

F-28

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

SWITCH BOARD TEST (CONT.)

Apply Positive Apply Negative
Test Prove to

Test Probe to

Terminal

Terminal

Test Result

Conclusion Repair Action

Next Procedure Notes

12

401/403

Greater than

OK

None

Continue

1K ohm

Less than

Shorted

Replace both

Snubber Test

100 ohms

Switch Boards

401/403

12

Less than

OK

None

Continue

100 ohms

Greater than

Open

Replace both

Snubber Test

1K ohm

Switch Boards

9

402/404

Less than

OK

None

Continue

100 ohms

Greater than

Open

Replace both

Snubber Test

1K ohm

Switch Boards

402/404

9

Greater than

OK

None

Continue

1K ohm

Less than

Shorted

Replace both

Snubber Test

100 ohms

Switch Boards

TABLE F.3

SWITCH BOARD RESISTANCE CHECKS

Advertising