TROUBLESHOOTING & REPAIR

TEST PROCEDURE

1. Turn Input Power Switch OFF

2. Perform Input Capacitor Discharge test as

described in the Maintenance Section.

3. Remove the four screws that hold the Control Panel

to the frame.

4. Move the Control Panel forward and to the left so

that there is access to the Control PC Board. Be
careful not to stress any of the connections to the
Control Panel.

5. Set the Output Terminals Switch to the ON position.

6. Turn the Input Power Switch ON.

FIGURE F.2 - REMOVING CONTROL PANEL

OUTPUT PILOT CIRCUIT TEST(cont.)