Detailed in table f.2, Troubleshooting & repair, Switch board test (cont.) – Lincoln Electric INVERTEC V300-PRO SVM105-B User Manual

Page 57

Advertising
background image

V300-PRO

TROUBLESHOOTING & REPAIR

F-27

F-27

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

SWITCH BOARD TEST (CONT.)

Apply Positive Apply Negative
Test Probe to

Test Probe to

Terminal

Terminal

Test Result

Conclusion Repair Action

Next Procedure Notes

1/8

12

Greater than

OK

None

Continue

1K ohm

Less than

Shorted

Replace both

Snubber Test

100 ohms

Switch Boards

12

1/8

Less than

OK

None

Continue

100 ohms

Greater than

Open

Replace both

Snubber Test

1K ohm

Switch Boards

9

4/5

Greater than

OK

None

Continue

1K ohm

Less than

Shorted

Replace both

Snubber Test

100 ohms

Switch Boards

4/5

9

Less than

OK

None

Continue

100 ohms

Greater than

Open

Replace both

Snubber Test

1K ohm

Switch Boards

1/8

9

Less than

OK

None

Continue

100 ohms

Greater than

Open

Replace both

Snubber Test

1K ohm

Switch Boards

9

1/8

Greater than

OK

None

Continue

1K ohm

Less than

Shorted

Replace both

Snubber Test

100 ohms

Switch Boards

12

4/5

Less than

OK

None

Continue

100 ohms

Greater than

Open

Replace both

Snubber Test

1K ohm

Switch Boards

4/5

12

Greater than

OK

None

Continue

1K ohm

Less than

Shorted

Replace both

Snubber Test

100 ohms

Switch Boards

NOTE: K ohm = ohm reading multiplied by 1000.
NOTE: Always make sure that Switch Boards are changed in matched pairs. Never mix an old style (different
part number) Switch Board with a newer style.

TABLE F.2

SWITCH BOARD RESISTANCE CHECKS

Advertising