Troubleshooting & repair, Capacitor removal and replacement (cont.) – Lincoln Electric INVERTEC V300-PRO SVM105-B User Manual

Page 82

Advertising
background image

V300-PRO

TROUBLESHOOTING & REPAIR

PROCEDURE

NOTE: When replacing capacitors, remove the

entire FET Heat Sink Assembly as a unit.

Remove and reassemble one side at a
time, using the other side as a model to
insure that all parts are reinstalled prop
erly

1. Perform the Input Filter Capacitor Discharge
Procedure.

2. Remove the two 3/8” hex nuts from the top of

the through bolts. The hex nuts are located on
top of the fan shroud See Figure F.25.

F-52

F-52

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

CAPACITOR REMOVAL AND REPLACEMENT (cont.)

FIGURE F.25 - REMOVING HEX NUTS

3. Turn the machine on it’s side as shown in Figure

F.26. Slide the plastic insulators that go through the
base to one side and pull out the through bolts,
being careful to save all of the insulation and stand-
off material. Set aside and save for reassembly.

FIGURE F26 - REMOVING THROUGH BOLTS

Advertising