Troubleshooting & repair, Snubber resistor test (cont.) – Lincoln Electric INVERTEC V300-PRO SVM105-B User Manual

Page 60

Advertising
background image

V300-PRO

TROUBLESHOOTING & REPAIR

1. Turn main Power off.

2. Perform Input Filter Capacitor Discharge proce-
dure.

3. Remove leads 401,402 403 & 404 from theSwitch
Boards.

4. Test for 25 ohms resistance from lead 401 to termi-

nal 12 on Switch Board.

a. If 25 ohms is measured, Resistor R4 is OK.

b. If 30 ohms or more is measured, Resistor R4 is

faulty and must be replaced.

c. If 20 ohms or less is measured, Resistor R4 is

faulty and must be replaced.

5. Repeat same procedures to test R5, R6, and R7 per

Table F.4.

F-30

F-30

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

SNUBBER RESISTOR TEST (cont.)

L8604-1

L8604-1

SWITCH

SWITCH

9R

W

12

WR

401/

403

1/

8

4/

5

402/

404

FIGURE F.9 - SNUBBER RESISTOR TEST POINTS

Check

Test Result

Conclusion

Next Test Step

Repair Action

Lead 401 to

25 ohms

OK

Continue

Terminal 12

>30 ohms

R4 open

Replace R4

<20 ohms

R4 faulty

Lead 402 to

25 ohms

OK

Continue

Terminal 9

>30 ohms

R5 open

Replace R5

<20 ohms

R5 faulty

Lead 403 to

25 ohms

OK

Continue

Terminal 12

>30 ohms

R6 open

Replace R6

<20 ohms

R6 faulty

Lead 404 to

25 ohms

OK

Continue

Terminal 9

>30 ohms

R7 open

Replace R7

<20 ohms

R7 faulty

TABLE F.4 SNUBBER RESISTORS TEST