Troubleshooting & repair – Lincoln Electric INVERTEC V300-PRO SVM105-B User Manual

Page 71

Advertising
background image

V300-PRO

TROUBLESHOOTING & REPAIR

8. Test for 15 VDC supply voltage between leads 302

and 275D on Power Board.

a.

If 15 VDC is present, test is OK. Go to step 9.

b.

If 15 VDC is not present, the Power Board may
be faulty. Check for 18 VAC input voltage at
lead 501 and 504 (J7).

If 18 VAC is present the Power Board is faulty
and must be replaced.

9. Test for 0-1 VDC (DC trigger circuit) between leads

305 and 275D on Power Board.

a.

If 0-1 VDC is present, DC trigger circuit is oper-
ating properly.

b.

If 15 VDC is present, go to step 10.

10. Test for 0-1 VDC between leads 301 and 275D on

Power Board.

a.

If 0-1 VDC is present, AC trigger, Control
Board, and Power Board are operating proper-
ly.

b.

If 15 VDC is present, go to Thermal Protection
AC Trigger Circuit Test .

F-41

F-41

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

OVERVOLTAGE PROTECTION DC TRIGGER CIRCUIT TEST (cont.)

FIGURE F.18 - POWER BOARD TEST POINTS

POWER BOARD

J6

J7

J14

L8033

501

313

311

309 310

504

302

305

301

212A

211A

275D