Troubleshooting & repair, Thermal protection ac trigger circuit (cont.) – Lincoln Electric INVERTEC V300-PRO SVM105-B User Manual

Page 74

Advertising
background image

V300-PRO

TROUBLESHOOTING & REPAIR

TEST PROCEDURE

1. Turn main power OFF.

2. Perform Input Filter Capacitor Discharge proce-

dure detailed in this section.

3. Detach the following PC boards so you can gain

access to and have ample room to perform the
tests. (Do not disconnect from wiring harness.)

Power Board

Control Board

NOTE:

Do not disconnect any wires. The machine

must be functional to perform test.

F-44