TROUBLESHOOTING AND REPAIR

F-14

F-14

POWER MIG® 215

INPUT VOLTAGE

TEST POINTS

EXPECTED VOLTAGE READING

11.9-13.0 VAC

14.1-15.2 VAC

16.2-17.5 VAC

18.4-19.7 VAC

20.5-22.0 VAC

22.7-24.2 VAC

24.8-26.5 VAC

26.9-28.8 VAC

X1-X2

X1-X3

X1-X4

X1-X5

X1-X6

X1-X7

X1-X8

X9-X10

230 VAC

230 VAC

230 VAC

230 VAC

230 VAC

230 VAC

230 VAC

230 VAC

TABLE F.1. Test Points

12. If ALL the voltages tested are incorrect

or missing, test for correct nameplate
input voltage between the H1 lead at the
ON/OFF POWER SWITCH to H2 or H3
at the reconnect panel. Voltage tested
will vary depending on input voltage con-
nection. See Wiring Diagram for test
point locations.

A. If the input voltage test is incorrect,

check for loose or broken leads between
the reconnect panel and the ON/OFF
POWER SWITCH.

B. Test the ON/OFF POWER SWITCH for

proper operation.

13. If the correct nameplate voltage is being

applied to the main transformer and one
or more of the secondary voltages are
missing or are incorrect, the main trans-
former may be faulty. Replace.

14. When test is complete, replace tool tray,

case sides and top.