TROUBLESHOOTING AND REPAIR

F-24

F-24

POWER MIG® 215

NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM (MAX TAP “G”)

20.0 V

1.0 ms

0 Volts

This is a typical DC output voltage wave-
form generated from a properly operat-
ing machine. Note that each vertical
division represents 20 volts and that
each horizontal division represents 1.0
milliseconds in time.

NOTE: Scope probes connected at

machine output terminals: (+)
probe to electrode, (-) probe to
work.

Volts/Div.................................20V/Div

Horizontal Sweep..............1.0 ms/Div

Coupling........................................DC

Trigger....................................Internal

SCOPE SETTINGS