OUTPUT BRIDGE RECTIFIER TEST (continued)

TEST PROCEDURE

1. Remove input power to the POWER

MIG® 215 machine.

2. Using the 3/8” nutdriver, remove the left

case side.

3. Locate and disconnect the negative lead

from the output rectifier bridge assembly.
Be sure there is no electrical contact
between the rectifier and the lead. See
Figure F.6.

NOTE: Do not disassemble the rectifier

assembly.

4. Test for “shorted” or “leaky” diodes by

checking from the anodes to the cathodes
of the diode heatsink plates. The
readings should be high resistance in
one polarity and low resistance in the
opposite polarity.

5. If any of the diodes are “leaky” or

“shorted” the output rectifier assembly
should be replaced.

6. When the test is complete, replace the

negative output lead previously removed.

7. Replace the left case side.