See figure f.17, Troubleshooting and repair, Main transformer replacement (continued) – Lincoln Electric POWER MIG SVM167-A User Manual

Page 79

Advertising
background image

F-43

TROUBLESHOOTING AND REPAIR

F-43

POWER MIG® 215

MAIN TRANSFORMER REPLACEMENT (Continued)

15. Carefully maneuver the main transformer

out the left side of the machine.

NOTE: Two people may be needed to maneu-

ver the main transformer out of the
machine.

REPLACEMENT

1. Carefully maneuver the new main trans-

former back into the machine and onto its
mounting studs.

2. Using a 1/2” nutdriver, mount the main trans-

former in its proper position.

3. Reconnect leads 118 and 121 previously

removed.

4. Using a 5/16” nutdriver, close the rear

access panel previously opened.

5. Reconnect lead X1 to the output diode

bridge rectifier.

6. Reconnect leads X8, X7, X6, X5, X4, X3, &

X2 previously removed from the switch
assembly.

7. Reconnect lead H1B and the other associat-

ed lead connected to the same terminal.
These leads are connected to the ON/OFF
switch.

8. Replace any necessary cable ties and wiring

harnesses.

9. Reconnect leads X9, X10, 104B, & 104C.

See Wiring Diagram.

10. Using a 5/16” nutdriver, replace the tool tray.

11. Using a 3/8” nutdriver, replace both sides of

the case wraparound cover.

X10

X9

104B

104C

H1B

FIGURE F.17. - LEADS X9, X10, 104B,104C, & H1B