Observing Boot Messages

A-4

INA Module Installation and Configuration Guide

Use Table A-2 to interpret possible diagnostic boot messages.

Table A-2

Interpreting Diagnostic Boot Messages

Field

Possible Message

Explanation

INA PROM

N

Version number of the
installed boot PROM.

Testing System Clock

ERROR

This error indicates a boot
failure. Record all
information to this point
and contact Lucent
technical support.

Sizing System Memory

ERROR at failed
memory address.

This error indicates a boot
failure. Record all
information to this point
and contact Lucent
technical support.

CPU Type

486DX5-133

The type of CPU installed.

Starting FLASH Boot

N/A

N/A

Flash Memory

Am29F016 4096K

Nonvolatile RAM brand
name and size in kilobytes.

16384

16384

Counter for system
memory dynamic RAM
(DRAM) size. If the size
counter freezes, record all
information to this point
and contact Lucent
technical support.

Verifying Load Module Checksum

Invalid Length for
Flash at RAM
address.

This error indicates a boot
failure. Record all
information to this point
and contact Lucent
technical support.

Starting Loader

N/A

N/A

Testing High Memory

ERROR at failed
memory address

This error indicates a boot
failure. Record all
information to this point
and contact Lucent
technical support.