Ina module maintenance options, Error events – Lucent Technologies Network Access Module User Manual

Page 63

Advertising
background image

C-3

INA Module Maintenance Options

Note – For T1 configurations, you can assign a channel to the router only if the channel
is Unequipped from a switch perspective. For PRI configurations, you can assign a
channel to the router only if the channel is not used in a B channel group or a line pool
on the switch.

Note – For the router to recognize a change in channel assignments, you must reboot
the router either from its command line interface or by pressing the reboot button on
the INA module.

You can view a summary of DSU channel assignments by using the following sequence
on your system programming console.

Menu: SysProg

Start

LinesTrunks

More

More

CSU/DSU

Slot#

Enter

ChannelSel

Inspect

All channels are listed and marked with one of the selections shown in Table C-2:

Use the following sequence on your system programming console to unassign channels
from the router.

Menu: SysProg

Start

LinesTrunks

More

More

CSU/DSU

Slot#

Enter

ChannelSel

Channel#

Delete

You must repeat this sequence for each channel to be unassigned from the router.

INA Module Maintenance Options

The 100R module has improved T1/PRI error event reporting and has an expanded set
of demand tests. All 100D module maintenance options are also included.

Error Events

The INA module provides three additional error event counts as well as the ability to
manually clear these error event counts. Included are

24-hour event totals

Current events

Selected interval events

Clearing error events

Table C-2

Inspect DSU Channel Assignments

Selection

Description

R

The channel is assigned to the router.

S

The channel is assigned to the switch.

U

The channel is assigned to neither the router nor the
switch.