24 hour event totals – Lucent Technologies Network Access Module User Manual

Page 64

Advertising
background image

INA Module Maintenance Options

C-4

INA Module Installation and Configuration Guide

Note – The additional error event counts are cleared whenever the INA module is reset.
Be sure to view the error events before resetting the module or busying out the module.

From your system programming console, use the following sequence to access the INA
module Error Events screen. Be sure to select the corresponding INA module slot
number.

Menu: Maintenance

Slot

Slot#

Enter

Error Events

The Current Hour and Previous Hour error event screens that are also used on the 100D
module are available on the INA module. Clearing the new error event counts does not
affect the Current Hour and Previous Hour error event counts. Because the Current
Hour and Previous Hour statistics are computed with a different algorithm, Current
Hour and Previous Hour counts do not match the newer counts.

24 Hour Event Totals

The 24-hour total error event screen reports cumulative error statistics spanning the
past 24 hours. The current event totals are not included in this report. From your
system programming console, use the following sequence to access the INA 24 Hr Total
screen. Be sure to select the corresponding INA module slot number.

Menu: Maintenance

Slot

Slot#

Enter

Error Events

24 hr total

This screen provides statistics related to the health of the T1/PRI interface. These
statistics are summarized in Table C-3.

Table C-3

24-Hour Total Error Line Items

Item

Description

24 Hour Slot xx

xx is the slot currently being reported on.

nn Valid
Intervals

nn is the number of valid historical 15-minute
intervals from the past 24 hours. A valid historical
interval is one for which data has been captured while
the system was running. During a valid interval, data
has not been lost due to a clearing of error events or a
board reset. A board reset can occur during a reset,
busy-out, frigid start, cold start or power outage.

MIS

Misframes.

SLP

Slips.

ES

Errored Seconds.

BS

Bursty errored seconds

.

SEC

Severely errored seconds.

FS

Failed seconds.

BPV

Bipolar violations.