Lakeshore Learning Materials 647 User Manual

Page 43

Advertising
background image

Lake Shore Model 647 Magnet Power Supply User’s Manual

Remote Operation

4-13

RI?:

Remote Inhibit Status Query

Input:

RI?

Returned: 0 if the remote inhibit is inactive, or 1 if it is active.

Remarks: One character plus up to two terminators are returned.

VOUT? (V?):

Output Voltage Query

Input:

VOUT? or V?

Returned: A number between 0 and ±32.0000 V.

Remarks: Returns nine characters plus up to two terminators.

VMAX:

Programs an upper (soft) voltage limit that the unit will accept.

Input: VMAX[voltage] where

[voltage] = 0 to +32.0000 V.

Remarks: Normal resolution truncates the value to 0.01 place. High resolution truncates the value to the

0.001 place. The initial condition is +000.0000 V. The voltage limit is always forced to a plus.

VMAX?:

Voltage Limit Query.

Input: VMAX?

Returned: A value between 0 and +32.0000 V.

Remarks: Returns a nine character value with up to two terminators.

VSET (V):

Programs the output voltage in the voltage mode.

Input: VSET[voltage] or V[voltage] where

[voltage] = 0 to +32.0000 V.

Remarks: Normal resolution truncates the value to 0.01 place. High resolution truncates the value to the

0.001 place. The initial condition is +00.0000 V. The voltage setting is always forced to a “+.”
Setting is limited by VMAX. Control Bus inputs 4 places, display rounds to 0.01 or 0.001 place.

VSET?:

Output Voltage Setting Query.

Input: VSET?

Returned: A value between 0 and +32.0000 V.

Remarks: Returns a nine character value with up to two terminators.

Advertising