Lake Shore Model 647 Magnet Power Supply User’s Manual

5-7

Troubleshooting

5.6 IEEE-488 INTERFACE CONNECTOR
(When Model 6224 Option Is Present)
Connect to the rear MPS IEEE-488 Interface

connector with cables specified in the IEEE-488-

1978 standard document. The cable has 24

conductors with an outer shield. The connectors at

each end are 24-way Amphenol 57 Series (or

equivalent) with piggyback receptacles to daisy-

chain multiple devices. Secure the connectors in the

receptacles by a pair of captive locking screws with

metric threads.

The total length of cable allowed in a system is 2

meters for each device on the bus, or 20 meters

total for a maximum of 15 devices. The figure below

and the table to the right shows the IEEE-488

Interface connector pin location and signal names.

Figure 5-3

IEEE-488 Interface Connector

SH1 AH1 T5 L4 SR1 RL1 PP0 DC1 DT0 C0 E1

1

2

11 1

0

9

8

7

6

5

4

3

2

1

2

4

2

3

2

2

2

1

2

0

1

9

1

8

1

7

1

6

1

5

1

4

1

3

5.7 SERIAL INTERFACE CABLE AND ADAPTERS
To aid in Serial Interface troubleshooting, the figures below provide wiring information for the cable assembly

and the two mating adapters.

Figure 5-4 Model 2001 RJ-11 Cable Assembly Wiring

6
543

21

6543

21

TxD
Gnd
Gnd
RxD

YELL OW

GREEN

RED

BLACK

5

4

3

2

1

9

8

7

6

1 2 3 4 5 6

RxD

Gnd

TxD

Figure 5-5 Model 2002 RJ-11

to DB-9 Adapter Wiring

DB-9

CONNECTOR

RJ-11

RECEPTACLE

Figure 5-6 Model 2003 RJ-11

to DB-25 Adapter Wiring

1

3

1

2

11

1

09

8

7

6

5

4

3

2

1

2

5

2

4

2

3

2

2

2

1

2

0

1

9

1

8

1

7

1

6

1

5

1

4

1 2 3 4 5 6

RxD

Gnd

TxD

DB-25

CONNECTOR

RJ-11

RECEPTACLE

= Not Used

PIN

SYMBOL

DESCRIPTION

1
2
3
4
5
6
7
8
9

10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

DIO1
DIO2
DIO3
DIO4

EOI

DAV

NRFD
NDAC

IFC

SRQ

ATN

SHIELD

DIO5
DIO6
DIO7
DIO8

REN

GND 6
GND 7
GND 8
GND 9

GND 10

GND11

GND

Data Input/Output Line 1
Data Input/Output Line 2
Data Input/Output Line 3
Data Input/Output Line 4
End Or Identify
Data Valid
Not Ready For Data
Not Data Accepted
Interface Clear
Service Request
Attention
Cable Shield
Data Input/Output Line 5
Data Input/Output Line 6
Data Input/Output Line 7
Data Input/Output Line 8
Remote Enable
Ground Wire – Twisted pair with DAV
Ground Wire – Twisted pair with NRFD
Ground Wire – Twisted pair with NDAC
Ground Wire – Twisted pair with IFC
Ground Wire – Twisted pair with SRQ
Ground Wire – Twisted pair with ATN
Logic Ground