13. Clear the leads in preparation for remov-
ing the stator/end bracket.
14. Lift the eight brushes from the commuta-
tor. Note the position of the brushes for
reassembly.
TROUBLESHOOTING & REPAIR
F-45
F-45
Classic III and IIID
ALTERNATOR STATOR REMOVAL
AND REPLACEMENT
(continued)
FIGURE F.20 - GENERATOR BRUSH HOLDER CABLE REMOVAL
GENERNATOR
BRUSH HOLDER/COIL
CABLES (4)
15. With the 1/2" wrench, disconnect and
clear the four heavy cables from the gen-
erator brush holders to the coils in the
generator frame. It is not necessary to
remove the brush holder jumper cables.
See Figure F.20. Label leads and posi-
tions for re-assembly.