13. Clear the leads in preparation for remov-

ing the stator/end bracket.

14. Lift the eight brushes from the commuta-

tor. Note the position of the brushes for
reassembly.

TROUBLESHOOTING & REPAIR

F-45

F-45

Classic III and IIID

ALTERNATOR STATOR REMOVAL

AND REPLACEMENT

(continued)

FIGURE F.20 - GENERATOR BRUSH HOLDER CABLE REMOVAL

GENERNATOR

BRUSH HOLDER/COIL

CABLES (4)

15. With the 1/2" wrench, disconnect and

clear the four heavy cables from the gen-
erator brush holders to the coils in the
generator frame. It is not necessary to
remove the brush holder jumper cables.
See Figure F.20. Label leads and posi-
tions for re-assembly.