Er to the, Normal open, Troubleshooting & repair – Lincoln Electric CLASSIC III SVM 137-A User Manual
Page 94
Advertising
TROUBLESHOOTING & REPAIR
F-34
F-34
Classic III and IIID
This is the typical auxiliary output
voltage generated from a properly
operating machine. Note that each
vertical division represents 50 volts
and that each horizontal division rep-
resents 5 milliseconds in time.
Note: Scope probes connected at
machine 115VAC receptacle.
SCOPE SETTINGS
Volts/Div .....................50V/Div.
Horizontal Sweep .....5 ms/Div.
Coupling.............................DC
Trigger .........................Internal
NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM (115VAC SUPPLY)
HIGH IDLE – NO LOAD – FINE CURRENT CONTROL RHEOSTAT AT MAXIMUM
CH1
0 volts
5 ms
50 volts
16.6 ms
Advertising