Troubleshooting & repair, Alternator rotor test (continued) – Lincoln Electric CLASSIC III SVM 137-A User Manual

Page 77

Advertising
background image

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

TROUBLESHOOTING & REPAIR

F-17

F-17

Classic III and IIID

FIGURE F.3 – MEASURING ROTOR RESISTANCE TO GROUND

7. Measure the rotor resistance to ground.

a. Set the ohmmeter on the high scale

(X100,000).

b. Place one probe on either of the rotor

slip rings. Place the other probe on any
good, unpainted ground. See Figure F.3.

c. Check the resistance.

It should read

very high, at least 0.5 megohm (500,000
ohms).

If the test does not meet the resistance
specifications, then the rotor may be
faulty. Replace the rotor.

8. Replace the brushes on the slip rings. Make

sure they are seated correctly.

9. Reinstall the alternator cover and wrap-

around.

ALTERNATOR ROTOR TEST

(continued)

Advertising