TROUBLESHOOTING & REPAIR

F-55

F-55

Classic III and IIID

RETEST AFTER REPAIR

Retest a machine:

• If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the

machine’s electrical characteristics.

OR

• If you repair or replace any electrical components.

ENGINE OUTPUT

Mode

No Load RPM

Load RPM

Low Idle

1325 - 1475

NA

High Idle

1780 - 1810

1650 - 1750

WELDER DC OUTPUT

Current Control

Current Selector

Open Circuit

Load Volts

Load Amps

Rheostat

Switch

Voltage

Maximum

Maximum

91 - 98.5

36 - 45 Gas

350

Maximum

Maximum

91 - 98.5

38 - 47 Diesel

350

AC AUXILIARY POWER RECEPTACLE OUTPUT

230 Volt Receptacle

115 Volt Receptacle

Open Circuit

Load Volts

Load Amps

Open Circuit

Load Volts

Load Amps

Voltage

Voltage

240 - 254

210 - 225

13.8

118 -128

103 - 112

26.0

FIELD AMPS AND VOLTS

(Current Rheostat at Maximum)

Exciter DC Volts

Shunt Field Amps

Alt. Rotor Amps

RPM

123 - 133

2.0 - 2.4

2.2 - 2.6

1780 - 1810