background image

CONNECTION OF THE LN-25 TO THE
CLASSIC III OR CLASSIC IIID (EQUIPPED
WITH K623-1 WIRE FEED MODULE)
“ACROSS THE ARC” (SEE FIGURE C.4.)

1. Shut the welder off.

2. Connect the electrode cable from the LN-25 to the

“+” terminal of the welder. Connect the work cable
to the “CV–” terminal of the welder.

NOTE: Welding cable must be sized for current and
duty cycle of application.

NOTE: Figure C.4 shows the electrode connected for
positive polarity. To change polarity, shut the welder
off and reverse the electrode and work cables at the

Classic III or Classic IIID

output terminals. Reverse the

LN-25 polarity switch.

3. Connect the K444-2 remote control cable to the 14

pin amphenol on the wire feed module.

4. Attach the single lead from the LN-25 control box

to the work using the spring clip on the end of the
lead. This is only a control lead — it carries no
welding current.

5. Place the IDLER switch in the “HIGH” position.

6. Adjust wire feed speed and voltage at the LN-25.

ACCESSORIES

C-7

C-7

Classic III and IIID

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

FIGURE C.4

CLASSIC III OR CLASSIC IIID/LN-25 ACROSS THE ARC CONNECTION DIAGRAM

TO
WORK

14 PIN
AMPHENOL

WORK CLIP
LEAD TO WORK

LN-25 WIRE FEEDER
WITH K444-2 REMOTE
VOLTAGECONTROL OPTION

ELECTRODE CABLE

CV-

+