background image

TO USE THE CLASSIC III OR CLASSIC
IIID FOR DC WIRE FEED WELDING
(CONSTANT VOLTAGE WITH WIRE FEED
MODULE):

1.

Connect the LN-25, LN-23P, or LN-7 Wire Feeder.
Follow the installation instructions provided with
the wire feeder.

2.

Set the machine for CV operation.

3.

Start the engine. See

Engine Operation in this

section of the manual.

4.

Set the Idler Switch to "AUTO."

5.

Set the CURRENT RANGE SELECTOR to a set-
ting appropriate for your wire size and wire feed
speed. See Table B.1 for recommended settings.

6.

Set the VOLTAGE ADJUSTMENT to the setting
that gives the best arc characteristics for the range
selected.

7.

Pull the gun trigger and begin welding.

OPERATION

B-12

B-12

Classic III and IIID

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Section TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

Retur

n to Master TOC

TABLE B.1

RANGE SETTINGS FOR WIRE SIZE/SPEED

Diameter (inches)

Wire Speed Range

Appropriate Current Range

(inches/minute)

.035

80-110

80 to 130 Amps

.045

70-130

120 to 190 Amps

.068

40-90

150 to 240 Amps