FUNCTION PROBLEMS

Observe Safety Guidelines detailed in the beginning of this manual.

PROBLEMS

(SYMPTOMS)

POSSIBLE AREAS OF

MISADJUSTMENT(S)

RECOMMENDED

COURSE OF ACTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.

CAUTION

No current regulation in the Stick
mode. Low open circuit voltage.

1. Make sure the machine is set-up

and configured correctly for the
Stick mode,

1. The Superimposition Board may

be faulty

2. The Output Module Transistor

Board may be faulty. See the
Secondary

Output

Board

Assembly Test and Wiring
Diagram.

There is no response to changes to
the output control settings. No cur-
rent regulation in all modes.

1. Make sure the correct input volt-

age is applied to the machine.
230 or 115VAC.

1. The Control/Display board may

be faulty.