Troubleshooting and repair, Input filter board, Input filter board test (continued) – Lincoln Electric INVERTEC SVM161-A User Manual
Page 56
Advertising
INPUT FILTER BOARD
FIGURE F.4 – INPUT FILTER BOARD LOCATION
INPUT FILTER BOARD TEST (continued)
PROCEDURE
1. Remove input power to the V205-T.
2. Using a phillips head screwdriver, remove the
case wraparound.
3. Perform the Input Filter Capacitor Discharge
Procedure detailed earlier in this section.
4. Locate the Input Filter board. See Figure F.4.
6. See Figure F.5 for voltage checks.
TROUBLESHOOTING AND REPAIR
F-16
F-16
INVERTEC® V205-T AC/DC™