Per tables f.15, f.16, f.17 & f18, Troubleshooting and repair – Lincoln Electric INVERTEC SVM161-A User Manual

Page 85

Advertising
background image

TABLE F.15 – LED FUNCTION

TABLE F.16 – FEEDBACK VOLTAGE SIGNALS

MAIN INVERTER BOARD

“WELDING LOGIC AND INVERTER” SECTION TEST (continued)

TROUBLESHOOTING AND REPAIR

F-45

F-45

INVERTEC® V205-T AC/DC™

TABLE F.18 – LED (CHECK IN STICK MODE)

Generator/Mode

ON/STICK

ON/STICK

ON/STICK

ON/STICK

Component

L11

L12

L13

L14

Value

ON AND FLASHING

ON AND FLASHING

ON AND FLASHING

ON AND FLASHING

Generator/Mode

ON/STICK

ON/STICK

ON/STICK

ON/STICK

Component

MF11

MF12

MF15

MF16

G[+],S[-]

3.75 VDC

3.75 VDC

3.75 VDC

3.75 VDC

D[+],S[-]

178 VDC

260 VDC

260 VDC

34 VDC

TABLE F.17 – VOLTAGE CHECKS WITH 115 VAC APPLIED TO MACHINE

Machine/Mode

ON/TIG

Component

TP15-TP14

Value

-2 VDC @ 100A
-4 VDC @ 200A

Condition

WELDING ON:

CURRENT

FEEDBACK

ON/STICK

TP16-TP14

4.3 VDC

OPEN CIRCUIT

VOLTAGE

CONDITION

WELDING ON:

VOLTAGE

FEEDBACK

ON/TIG

TP19-TP14

2 VDC @ 100A
4 VDC @ 200A

WELDING ON:

CURRENT

REFERENCE

Machine/Mode

ON/STICK

ON

ON

Component

L8

L9

TP31-TP9

Value

-------

-------

2.56 VDC

Condition

ON AND FLASHING

OFF

-------

Note

POT SIGNAL

THERMAL

ALWAYS

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Advertising