Per tables f.15, f.16, f.17 & f18, Troubleshooting and repair – Lincoln Electric INVERTEC SVM161-A User Manual
Page 85
TABLE F.15 – LED FUNCTION
TABLE F.16 – FEEDBACK VOLTAGE SIGNALS
MAIN INVERTER BOARD
“WELDING LOGIC AND INVERTER” SECTION TEST (continued)
TROUBLESHOOTING AND REPAIR
F-45
F-45
INVERTEC® V205-T AC/DC™
TABLE F.18 – LED (CHECK IN STICK MODE)
Generator/Mode
ON/STICK
ON/STICK
ON/STICK
ON/STICK
Component
L11
L12
L13
L14
Value
ON AND FLASHING
ON AND FLASHING
ON AND FLASHING
ON AND FLASHING
Generator/Mode
ON/STICK
ON/STICK
ON/STICK
ON/STICK
Component
MF11
MF12
MF15
MF16
G[+],S[-]
3.75 VDC
3.75 VDC
3.75 VDC
3.75 VDC
D[+],S[-]
178 VDC
260 VDC
260 VDC
34 VDC
TABLE F.17 – VOLTAGE CHECKS WITH 115 VAC APPLIED TO MACHINE
Machine/Mode
ON/TIG
Component
TP15-TP14
Value
-2 VDC @ 100A
-4 VDC @ 200A
Condition
WELDING ON:
CURRENT
FEEDBACK
ON/STICK
TP16-TP14
4.3 VDC
OPEN CIRCUIT
VOLTAGE
CONDITION
WELDING ON:
VOLTAGE
FEEDBACK
ON/TIG
TP19-TP14
2 VDC @ 100A
4 VDC @ 200A
WELDING ON:
CURRENT
REFERENCE
Machine/Mode
ON/STICK
ON
ON
Component
L8
L9
TP31-TP9
Value
-------
-------
2.56 VDC
Condition
ON AND FLASHING
OFF
-------
Note
POT SIGNAL
THERMAL
ALWAYS