Troubleshooting and repair, External diagnostics, F-9 invertec® v205-t ac/dc – Lincoln Electric INVERTEC SVM161-A User Manual

Page 49: Power supply led (green), Alarm led (yellow), Display, Under/overvoltage alarm thresholds

Advertising
background image

TROUBLESHOOTING AND REPAIR

F-9

F-9

INVERTEC® V205-T AC/DC™

EXTERNAL DIAGNOSTICS

®

PARAMETER

SELECT

/

HOLD

PULSE ON

UPSLOPE

% ON TIME

DOWNSLOPE

FINISH

CURRENT

BACKGROUND

CURRENT

POSTFLOW

WELD

CURRENT

sec

sec

sec

MODE

STICK

DC TIG

AC TIG

WARNING

TRIGGER

4-STEP

2-STEP

LOCAL

REMOTE

OUTPUT

A

PULSE FREQUENCY

Hz

V

AC FREQUENCY Hz

AC BALANCE % EN

Power Supply

Alarm

Display

Output Current Control

Output

Set-up Parameter
Select Button

Figure F.1 External Diagnostics

The front panel controls the status of the equipment and shows it to the operator via the LED’s and the display. Immediately
after switch-on of the equipment, the front panel executes an autotest operation, all LED’s will light up and the display
shows”200” as a check.

Power supply LED (GREEN)

Indicates the machine switch-on status. Always present if the panel, and therefor the machine, is correctly powered.

Alarm LED (YELLOW)

Indicates a protection status of the equipment. Comes on to indicate the presence of a problem. The type of alarm is indi-
cated in the display by an error code (see below).

Display

Immediately after the autotest operations above, the display briefly shows the software version of control panel (e.g. 01).
It indicates the welding parameters requested by the operator (with the help of the other keys) and immediately after striking
of the arc sets to reading mode, providing the real value of the current delivered by generator. It indicates a protection status
via codes with simultaneous switch-on of the yellow LED.

Indic.

E10

E11

E12

E13

E14

Type of Error

Internal Heatsink Overtemp.

Power Supply Overvoltage

Power Supply Undervoltage

Front Panel Memory Error

Front Panel Secondary

Memory Error

Action

Remove upper cover, check internal temperature, check thermal device status

(N.C.). See machine layout.

Remove upper cover, check that the power supply voltage is within the established

range (+/- 15%). Check reading voltage on 15.14.314 CN1 (See Fig. 9)

Remove upper cover, check that the power supply voltage is within the established

range (+/- 15%). Check reading voltage on 15.14.315 CN1 (See Fig. 9)

Remove upper cover, check front panel power supplies. Perform front panel reset*

test and replace if necessary.

Remove upper cover, check front panel power supplies. Perform front panel reset*

test and replace if necessary.

*Note: to reset front panel (memory) see procedure in “Set-up parameters” chapter below.

Normally, when cause(s) of alarm(s) is (are) removed, press one of the keys to exit from alarm status (or switch off and on

the machine).
Thermal alarm will be automatically reset by letting go down internal temperature: machine will execute a new autotest and
then start as in normal operation.
In case of error code E10, see also the three thermal switches in fig. below.
In case of error codes E11/E12, check input power supply voltage, with reference to the following table.

Under/Overvoltage alarm thresholds

Power supply rated

voltage

115 VAC

230 VAC

92 VAC

184 VAC

138 VAC

276 VAC

Overvoltage

Undervoltage

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Section

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC

Return

to

Master

T

OC