OPERATION
B-7
B-7
INVERTEC® V205-T AC/DC™
SET UP MENU
Many additional parameters can be modified via the
Set Up Menu. To access the Set Up Menu:
• Position the ON/OFF switch to OFF “0”.
• Depress and hold the Parameter select Push Button.
• Position the On/Off switch to on "I" at the back of the
machine; the input voltage light "Item 1" (green LED)
confirms normal operation.
• The SETUP mode is confirmed by a center "0" on the
Digital display “Item 6”.
- Rotate the Output / Parameter Adjust Knob,
the Digital Display shows the numbers corre-
sponding to the parameters in sequence;
stop at the desired parameter and push the
"Setup/Parameter Push Button".
- The number on the Digital display "Item 6" is
replaced by the value of the parameter that
can be modified through the Output /
Parameter adjust knob "Item 5".
- With parameter (9) all the modifications
made in the SETUP mode are cancelled and
the standard values set by Invertec® V205-T
AC/DC™ are restored.
- To exit the Set Up Menu, return to “0” and
press the Setup/Parameter Push Button
INDICATOR
PARAMETER
DEFAULT
0
Exit From Set Up
1
Not Used
2
Pre Flow Time (0 - 25 seconds)
0.5 sec.
3
Arc Force, percent above Peak Current for Stick only (0 - 100%)
30%
4
Hot Start, percent above Peak Current for Stick only (0 - 100%)
80%
5
Setting of AC wave Form
2 (Square)
0 = Sinusoidal
1 = Triangular
2 = Square
NOTE: This parameter limits maximum weld current, see "OUTPUT LIMITATIONS" section of the manual.
6
Min. Weld Current Value with Remote Control,for TIG only.
10 Amps
(6 Amps - Value set for Indicator 7)
7
Max. Weld Current Value with Remote Control,for TIG only.
Peak Current
(Value set for Indicator 6 - Peak Current)
NOTE: Peak Current (Max Weld Current) can be limited by input voltage, welding mode, AC TIG waveform and AC TIG frequency.
8
Touch Start or H.F. Start in DC TIG (0 = H.F. Start, 1 = touch Start)
0
This parameter is ignored in AC TIG Mode
9
Reset all Parameters, (including control panel settings)
10
Not Used
11
Not Used
12
2 Step Trigger Selection
1
0 = Restart Disabled
1 = Restart Enabled
13
4 Step Trigger Selection
0
0 = Restart Disabled
1 = Restart Enabled
14
Start Power , for TIG only
2.0
This function sets the initial start energy limit.
(1.0 = min., 5.0 = max.)
Note: If the machine does not initiate a welding arc it will repeat the
starting sequence with an increased start energy up to this limit.
Set this number to a higher setting than the factory default if
needed to improve starting of large diameter tungstens electrodes.