Using Setup Mode for Configuration

Table 4-24. Modem Mode Commands

Modem Mode
Command

Function

ATDTx.x.x.x,pppp or
ATDTx.x.x.x/pppp

Makes a connection to an IP address (x.x.x.x) and a remote port
number (pppp).

ATDTx.x.x.x

Makes a connection to an IP address (x.x.x.x) and the remote port
number defined within the unit.

ATD0.0.0.0

Forces the unit into Monitor Mode if a remote IP address and port
number are defined within the unit.

ATD

Forces the unit into Monitor Mode if a remote IP address and port
number are not defined within the unit.

ATDx.x.x.x

Makes a connection to an IP address (x.x.x.x) and the remote port
number defined within the unit.

ATH

Hangs up the connection (Entered as +++ATH ).

ATS0=n

Enables or disables connections from the network going to
the serial port.

n=0 disables the ability to make a connection from the network to
the serial port.

n=1-9 enables the ability to make a connection from the
network

to the serial port.

n>1-9 is invalid.

ATEn

Enables or disables character echo and responses.
n=0 disables character echo and responses.
n=1 enables character echo and responses.

ATVn

Enables 1-character response or full verbose.
n=0 enables 1-character response.
n=1 enables full verbose.

Note:

The unit recognizes these AT commands as single commands such as

ATE0 or ATV1; it does not recognize compound commands such as ATE0V.

Remote IP Address

This is the destination IP address used with an outgoing connection.

Remote Port

You must set the remote TCP port number for the unit to make outgoing connections.
This parameter defines the port number on the target host to which a connection is
attempted.

Note:

To connect an ASCII terminal to a host using the unit for login

purposes, use the remote port number 23 (Internet standard port number for
Telnet services).