Plasmon D875 - D2175 User Manual

Appendix D

Document Revision E

Page 73

2

Drive is clamped, can
not unclamp (checking
move to a drive)

Drive, drive
cables

Replace Drive, drive cables

38

1

Drive in service
state

In service state,
attempting to turn drive
off in maint menu

Follow operating instructions

2

In service state,
attempting to turn drive
on in maint menu

3

In service state,
attempting to put drive
in service state via
SCSI command

39

1

Drive not in ser-
vice state

Restoring drives, not in
a service state

Follow operating instructions

3F

1

Drive Addr con-
flict

Address conflict with
changer

Correct address in setup con-
figuration

2

Address conflict with
another drive

40

1

Not supported
by bus config.

Attempt to put drive in
service state via SCSI,
drive not supported by
current bus config.

2

Attempt to restore drive
via SCSI, drive not sup-
ported by current bus
config.

41

1

Drives overheat-
ing

Warning for an over
heating drive

Cabinet
Temp

Check room temp

42

1

Drives shut-
down - heat

Drive will be shutdown
due to overtemp condi-
tion, alert host of 90 sec
delay before shutdown

Cabinet
Temp

Check room temp

43

1

Low fan speed-
drive

Warning for low fan
speed in a drive module

Fan

Replace fan

44

1

Drive shutdown-
fan

Drive will be shutdown
due to fan failure, alert
host of 90 sec delay
before shutdown

Fan

Replace fan

Error
Code

(hex)

Sub-

code

Error

Description

Subcode

Description

Compo-

nent

Corrective Action