Plasmon LIBRARIES D2175 User Manual

Page 80

Advertising
background image

Appendix D

Plasmon D875 - D2175 User Manual

Page 78

Document Revision E

80

1

Element not
present

Checking move from an
invalid fixed slot loca-
tion

Correct host software

2

Checking move to an
invalid fixed slot loca-
tion

3

SCSI position attempt
to an invalid slot loca-
tion

81

1

Magazine not
present

Magazine not present
during verification of
installation

Replace magazine

2

Magazine not present
during recovery

84

1

Source is empty

Online check of
NVRAM says source
element is empty

Run Check Elements, Host
needs to check inventory

2

Online check of
NVRAM says source
element is empty, to
element is full (not
exchange command)

3

Src element = 1st desti-
nation element during
exchange command

85

1

Destination is full Online check of

NVRAM says destina-
tion element is full (not
an exchange com-
mand)

Run Check Elements, Host
needs to check inventory

2

Online check of
NVRAM says destina-
tion element is full
(picker address not
zero)

3

1st destination element
= 2nd destination ele-
ment during exchange
command

Error
Code

(hex)

Sub-

code

Error

Description

Subcode

Description

Compo-

nent

Corrective Action

Advertising
This manual is related to the following products: