32

Setup menus

USER menu

<TIME CODE>

(continued)

Item

Setting

No.

Superimposed

No.

Superimposed

Description

display

display

509

DF MODE

0000

DF

0001

NDF

510

RUN MODE

0000

REC

0001

FREE

511

TC OUT

0000

V OUT

REF

0001

TC_IN

512

VITC OUT

0000

SBC

0001

VAUX

The underline on the setting item denotes the initial setting.

SBC (Sub Code Data) area
This area exists independently from the video and audio data areas on the helical track, and it contains the time
code which complies with the SMPTE/EBU standard. As with the conventional LTC (Longitudinal Time Code), the
time code can be read even during rewinding and fast forwarding or when the tape has stopped.

VAUX (Video Auxiliary Data) area
This area exists inside the video data area on the helical track, and it contains additional information on the video
data.

<Note>
Control over the time code or user bit during tape playback is exercised using the data recorded in the SBC area.
In other words, it is exercised over all the data which has been recorded in the SBC area including the data shown
on the counter display in the center of the front panel and on the superimposed displays as well as the
communication data for a component such as the editing controller.

This selects the DF/NDF mode for CTL and TCG.
0: Drop frame mode.
1: Non-drop frame mode.
<Note>
No. 509 is valid when the CONTROL is LOCAL or LOCAL
ENA of item 004 to “ENA”.

This selects the time code generator run mode.
0: Generator runs only during recording.
1: Generator runs during usual operation.
<Note>
Even if “0” is selected, the time code generator runs during
usual operation when “1” is selected at the setting menu
No. 504 (REGEN MODE).

This is used to switch the phase of the time code, which is
output from the TIME CODE OUT connector, for the external
LTC input when the TC INT/EXT switch is at the EXT position.
(In EE mode only)
0: Time code is synchronized with output video signal.
1: Time code is synchronized with external time code input.

For selecting the method used to output the VITC which is to
be superimposed onto the output video signal.
0: During recording:

The input time code, which was selected using the setup
menu item No. 505 (EXT TC SEL) setting and TC IN/EXT
switch, is output as the VITC.
During playback:
The time code recorded in the SBC area is output as the
VITC.

1: During recording:

The time code detected from the input video signals is
output as the VITC.
During playback:
The time code recorded in the VAUX area is output as the
VITC.

<Note>
When video signals are recorded, the time code detected from
the input video signals is automatically recorded in the VAUX
area.