47

Warning

Priority

High

Description

Low

FAN STOP

Error No. lights when a fan motor stops operating.

VTR operation

Continued

SERVO NOT LOCKED Error No. lights when servo disturbances continue for

3 or more seconds during playback, recording or
editing.

Continued

LOW RF

Error No. lights when envelope levels approx. 1/3 that
of normal levels are detected for more than 1 sec.
during playback, recording or editing.

Continued

HIGH ERROR RATE

Error No. lights when the error rate increases and
correction/interpolation is performed on either the
video or audio playback signal.

Continued

Error No.

TV monitor display*

E-00*

(Err-00)

NO RF

This appears when a blank exceeding 1 second is
detected on the tape during playback.

Continued

E-09*

(Err-09)

E-01*

(Err-01)

E-10*

(Err-10)

E-02*

(Err-02)

* Displays when warning information is checked by pressing the DIAG button.

AUTO OFF mode

The following error number flashes on the counter display section.

VTR operation

Error No.

TV monitor display

Descriptions

(VTR measures)

E-20

DEW

EJECT

Any other

number

When condensation is detected, the error no. display
flashes, and the unit goes into EJECT mode. The drum
rotates after the cassette tape is ejected to remove
condensation.
When the condensation has been removed, the error no.
display disappears and the VTR may be used.
<Notes>
1) The drum rotates as soon as condensation is detected

when the unit is in EJECT mode.

2) When condensation is detected while a cassette tape is

inserted, drum rotation stops, the cassette tape is ejected
and the drum rotation begins again.

If any other number appears frequently, ask your dealer to
inspect the unit.