Pioneer SCSI-2 User Manual

Page 170

Advertising
background image

Read CD-DA

- 157 -

2.46

Read CD-DA (D8h)

IMPORTANT: This command applies only to models DRM-602X, DRM-624X, and the DR-U

Series drives.

Operation Code is (D8h).

The READ CD-DA command requests that the drive transfer CD-DA data and/or Sub Code

data.

The Starting Logical Block Address specifies the block where the READ operation begins.

The definition of the starting logical block address is as follows:

Starting Logical Block Address = (M-Ms) * 60 * 75 + (S-Ss) * 75 + (F-Fs)

(M, S, F) = absolute MSF address of the requested starting logical block

(Ms, Ss, Fs) = absolute MSF address of the first block of the first track

Sub Code Field:

Sub Code Field

CD-DA block length

Description

00h

2352 bytes

CD-DA data with no Sub Code

01h

2368 bytes

CD-DA data with Sub Q Code

02h

2448 bytes

CD-DA data with all Sub Code

03h

96 bytes

All Sub Code only

04 ~ FFh

Reserved

If the Sub Code field is set to 00h, the drive returns the CD-DA data without Sub Code data.

(Each block consists of 2352 bytes of digital audio data without any Sub Code data.)

If the Sub Code field is set to 01h, the drive returns the CD-DA data with Sub Q data. Each

block consists of 2368 bytes which includes 2352 bytes of digital audio data, 10 bytes of Sub Q

data and 6 bytes of zeros. Note: 16 bits of CRC for the Sub Q data are not transferred.

If the Sub Code field is set to 02h, the drive returns the CD-DA data with all Sub Code data.

(Each block consists of 2448 bytes which includes 2358 bytes of digital audio data and 96 bytes

of Sub Code data.)

If the Sub Code field is set to 03h, the drive returns 96 bytes of all Sub Code data only.

The Transfer Length specifies the number of contiguous CD-DA data blocks to be transferred.

Advertising