Read CD-XA

- 163 -

2.48

READ CD-XA (DBh)

IMPORTANT: This command applies only to models DRM-602X, DRM-624X, and the DR-U

Series drives.

Operation Code is (DBh).

Starting Address specifies the block where the operation begins.

Transfer Length specifies the number of contiguous CD-XA blocks to be transferred.

The READ CD-XA command requests that the drive transfer CD-XA data to the host.

The Starting Address is defined as follows.

Starting Address = M * 60 * 75 + (S-2) * 75 + F

M, S & F = the absolute MSF address of the requested starting address

CD-XA Format Field:

CD-XA Field

CD-XA Block Length

Description

00h

2048 bytes

User data only (no sub header)

0Fh

2352 bytes

All CD-XA sector data

1Fh

2646 bytes

All data with 294-byte Error Flags

Other Codes

Reserved

When the CD-XA Format field is set to 00h, the drive returns 2048 bytes CD-XA data in the

user data area without any Sub-header data. If the requested block is in a CD-XA Mode2/Form2

sector, only 2048 bytes user data will be returned and the remaining data will be discarded.

When the CD-XA Format field is set to 0Fh, the drive returns all 2352 bytes CD-XA sector

data.

When the CD-XA Format field is set to 1Fh, the drive returns the CD-XA data with Error Flag

data. Each block consists of 2646 bytes which includes the entire block of 2352 bytes CD-XA

data and a block of 294 bytes Error Flag data.

NOTE: The CD-XA block length is totally irrelevant to the logical block length set by Mode

Select Command.