Pioneer SCSI-2 User Manual

Page 32

Advertising
background image

Change Definition

- 19 -

2.3

Change Definition (40h)

When executed, the CHANGE DEFINITION command modifies the operating definition of the

drive regardless of the specified logical unit number.

A SCSI reset or BUS DEVICE RESET will not affect the definition changed by the CHANGE

DEFINITION command.

Cycling the power to the drive OFF and ON will cause the operating definition to revert to the

default setting.

If the CHANGE DEFINITION command did not execute successfully, the operating definition

will remain in the same status it was prior to the attempted execution of the CHANGE

DEFINITION command.

Operation Code is (40h).

Save Control Bit (SCB)

Must be set to “0” (FALSE).

The drive will not save the operating definition. A power reset will set the drive to its initial

operating definition.

Definition Parameter specifies the operating definition. The Definition Parameter field supports

the following field values:

00h

:

Use current operating definition

01h

:

SCSI-1 operating definition

02h

:

SCSI-1 operating definition

03h

:

SCSI-2 operating definition

04h~7Fh

:

Reserved

DRIVE NOTES:

This command is used by the DRM-604X.

Drives that are SCSI-2 only and will reject the CHANGE DEFINITION command are:

DRM-602X, DRM-624X, DRM-1804X and the DR-U Series drives

Advertising