p. 89

6

microprocessor control

microprocessor controlled muting

The Crest X-Series of Consoles* is equipped with a micro-con-

trolled Mute Controller which permits the user to set-up a series
of Mute Scenes, each controlling any combination of channels and
outputs.These Scenes can then be recalled, either singly or in
combination, to allow the operator to easily control the mutes
during a performance.

The Mute Controller features 128 Sequenced Scenes (Patches)
along with 8 Manual Mute Scenes.The 128 Patches can be stepped
through using a single button, or remotely activated by the use of
MIDI patch-change commands.The Patches can be combined with
the Manual Scenes to allow different combinations of Channel
mutes.

The following is a overview of the controls and indicators of the
Mute Controller and the Channels (see diagrams on previous
page).The following information pertains to X-Eight consoles with
Rev 1.12 firmware, and X-Monitor consoles with Rev 1.00
firmware.

12-12-01 Supplementary information....

1) To perform “FULL FACTORY RESET” of Micro Mute and VCA
settings hold up/down buttons upon power-up. This will clear all
memory and restore Micro Controller to factory presets.
2) Do not use the "uP" parameter with the setting "OFF" in the utility
menu until a newer EPROM version is released. Please submit your
console serial # and shipping address to [email protected] if
you wish to be on an EPROM distribution list for this event.
3) EOF stands for Edit On the Fly. A new parameter offered in the
utility menu. When selected it allows for spontaneous removal of a
mute you have programmed in as part of a current scene.