Rs-422, Chapter 5 – Printronix H-SERIES P7000 User Manual

Page 120

Advertising
background image

120

Chapter

5

RS-232 And RS-422 Serial Interfaces

Receive Data (RD). Serial data stream to the printer.

Transmit Status & Control Data (TD). Serial data stream from the printer for
transmitting status and control information to the host. Subject to protocol
selection.

Request To Send (RTS). Control signal from the printer. Subject to
configuration.

Clear To Send (CTS). Status signal to the printer indicating the host is ready
to receive data/status signals from the printer.

Data Set Ready (DSR). Status signal to the printer indicating the host is in a
ready condition.

Data Carrier Detect (DCD). Status signal to the printer. The ON condition is
required for the printer to receive data.

Data Terminal Ready (DTR). Control signal from the printer. Subject to
configuration.

RS-422

+RD, -RD.Serial data stream differentially received by printer.

+TD, -TD.Differentially driven serial data stream for transmitting status and
control information to the host. Subject to protocol selection.

NOTE:

±

RD and

±

TD form signal and return paths of a differential line signal.

Table 10. PSA3 RS-422 Serial Interface Connector Pin Assignments

Input Signals

Output Signals

Miscellaneous

Signal

Pin

Signal

Pin

Signal

Pin

- Receive Data

(-RD)

1

- Transmit Data

(-TD)

3

Chassis/Signal

Ground

5

+ Receive Data

(+RD)

6

+ Transmit Data

(+TD)

8

Advertising