Fault Messages

157

LOADING PROGRAM
INTO FLASH

No

The printer has deleted the
previous program from flash
memory and is loading the
new program into flash
memory.

No action is required.

NEW SPX DETECTED
PRESS ENTER

No

The printer detects an SPX
installed at the debug port
and the SPX is valid for the
printer.

Contact your authorized service

representative.

1

NON VOLATILE
MEMORY FAILED

No

Large emulations reduce the
amount of space available
for saving configurations,
which means that
sometimes fewer than eight
configurations can be saved.

Contact your authorized service

representative.

1

OLD RIBBON
Install New RBN

Yes

The sensor detects a ribbon
that was previously declared
to be at the end of its service
life.

Install a new ribbon.

ON LINE

N/A

Printer state message:
printer is online and in
communication with host.

No action is required.

ONLINE
28 CU NOT ENAB

Yes

Controller Unit Not Enabled.
Poll
time-out error. The printer
was not polled for one
minute across a coax
interface.

Check cable connection and
host system.

ONLINE
8344 FAILED*

No

Link-level code test detects
hardware failure.

Contact your authorized service

representative.

1

ONLINE
CU TIMED OUT

Yes

Controller Unit Timed Out.
The printer was not enabled
for one minute or more on a
coax interface.

Check cable connection and
host system.

PAP BAD TABLE*

No

Paper Bad Table. The paper
feed process on the
controller board has a
corrupted table.

Contact your authorized service

representative.

1

PAP BSY TOO LNG*

No

Paper Busy Too Long.
Firmware error on controller
board.

Contact your authorized service

representative.

1

Table 12. LCD Message Troubleshooting Table

Displayed Message

Can User

Correct?

Explanation

Solution