F-1

Appendix

APPENDIX F

HARDWARE JUMPER CONFIGURATION

Jumpers on the DCU (Data Control Unit) board are used to select a few configuration paĆ

rameters. These jumpers are installed for normal operation at the factory. However, certain

applications may require a modification to the jumper configuration. To change any of these

configuration jumpers, the DCU logic board must be removed. Table F-1 describes the jumpĆ

er configurations. To gain access to the DCU Printed Circuit Board Assembly (PCBA), the

right side panel and the card cage access panel must be removed as described in the following

procedures.

-

CAUTION -

Some configurations require cutting an etch and soldering on the PCBA. These

changes should only be performed by a trained technician.

- VORSICHT -

Manche Konfigurationen benötigen einen Ätzschnitt und Löten am PCBA. Diese

Änderungen sollten nur von einem geschulten Techniker vorgenommen werden.

Table F-1. Hardware Jumper Configuration

Jumper

Description

Description

E1A-E1B

E4A-E4B
E4B-E4C
E5A-E5B
E5B-E5C
E6A-E6B
E6B-E6C
E7A-E7B

E3A-E3B
E3B-E3C

E2A-E2B

Print Head Select 0
Print Head Select 1
RXCLK Input
Clock to 68901 RC Input
TXCLK Input
Timer C Output to Clock
NTXCLK Input
Clock to 68901 TC Input
Clock DPMC Phase 1
Clock DPMC Phase 2*
Clock CPU*

*Normal Installed Jumpers

*NOTE: Only one of the Serial Interface clocks can be selected by inserting the related

jumper. Selecting one of these clocks will require cutting the appropriate etch on the

PCBA: For jumper E4A-E4B, cut E4B-E4C; for jumper E5A-E5B, cut E5B-E5C;

for jumper E6A-E6B, cut E6B-E6C. These changes should only be performed by a

qualified technician.