Printronix P5000LJ Series User Manual

Page 253

Advertising
background image

Set Commands

253

set user add|del username

set user add eng

Add or remove a user on the NIC defined by

username

.

set user passwd username password

set user passwd eng mplex1

Assign a

password

to a defined user on the NIC. This

password

must

be less than eleven characters.

set user type username root|guest

set user type eng root

Assign root or guest privileges to a particular user defined by

username

.

Guest permissions allow viewing of settings only. Root permissions allow
complete control of the NIC.

set user from default

Set all user settings back to factory defaults.

set user from stored

Set all current user settings to the values stored in flash memory.

set user passwd snmp com_name

Sets the new SNMP R/W community name as the

com_name

value.

set var variablename variablestring

set var LANDSCAPE 0x1b 0x26 0x6c 0x31 0x4f

set var FINISH $FF $PCL-RST

Define a new variable to be used in header, trailer, or switch strings on
the NIC and call it

variablename

.

variablestring

can be a space-

separated list of words, hexadecimal numbers
(e.g., 0x04), or references to other pre-defined variables. It is easiest to
make up the

variablestring

with hexadecimal values as shown in the

example.

One variable counts as one element within header and trailer strings.

Defined variables are referenced in strings by placing an

$

before the

variable name (e.g.,

set model m1 trailer $FF

).

set var from default

Set all variable settings back to factory defaults.

set var from stored

Set all current variable settings to the values stored in flash memory.

Note

Be careful not to delete the

root

user, or you will be unable to configure

any further settings on the print server. You will have to go back to factory
defaults to correct this problem.

Advertising