background image

Lubrication & Maint./2000 Hour/24 Month

DPSG,RG34710,112

–19–07JAN02–1/5

Testing Thermostats Opening Temperature

TS281

–UN–23AUG88

High Pressure Fluids

RG8115A

–UN–15JAN98

Thermostat Cover-to-Water Pump Tube

A—Cover-To-Coolant Pump Tube

To Remove Thermostat(s)

NOTE: On some engines, the coolant manifold/thermostat

housing is an integral part of the cylinder head.

CAUTION: Explosive release of fluids from
pressurized cooling system can cause serious
burns. DO NOT drain coolant until it has cooled
below operating temperature. Always loosen
radiator pressure cap or drain valve slowly to
relieve pressure.

1. Visually inspect area around thermostat housing for

leaks.

2. Remove radiator pressure cap and partially drain

cooling system.

3. Remove thermostat cover-to-water pump tube (A) and

seal.

DPSG,RG34710,112

–19–07JAN02–2/5

RG7921A

–UN–13NOV97

Thermostat Cover

B—Thermostat Cover

4. Remove thermostat cover (B) with gasket.

5. Remove thermostat(s)

6. Remove and discard all gasket material. Clean gasket

surfaces.

7. Clean and check cover for cracks or damage.