PowerTec OMRG25204 User Manual

Page 98

Advertising
background image

Lubrication & Maint./2000 Hour/24 Month

OURGP11,000000C

–19–24JUN04–2/3

RG8019A

–UN–19JUN00

Engine Block Drain Valve

A—Engine Block Drain Valve
B—Engine Block Drain Plug
C—Engine Block Drain Plug

3. Open engine block drain valve (A) on left side of

engine. Drain all coolant from engine block.

NOTE: These engines use several different oil filter

adapters. Use either drain plug (B) or (C) to drain
coolant, whichever is more accessible for the oil
filter adapter on your engine.

4. Open radiator drain valve. Drain all coolant from

radiator.

5. Remove thermostats at this time, if not previously

done. Install cover (without thermostats) using old
gasket and tighten cap screws to 47 N•m (35 lb-ft).

6. Test thermostat opening temperature. (See Inspecting

Thermostats And Testing Opening Temperature in
Service As Required Section.)

7. Close all drain valves after coolant has drained.

CAUTION: Do not run engine longer than 10
minutes. Doing so may cause engine to
overheat which may cause burns when radiator
water is draining.

8. Fill the cooling system with clean water. Run the

engine about 10 minutes to stir up possible rust or
sediment.

9. Stop engine, pull off lower radiator hose and remove

radiator cap. Immediately drain the water from system
before rust and sediment settle.

10. After draining water, close drain valves. Reinstall

radiator cap and radiator hose and clamp. Fill the
cooling system with clean water and a heavy duty
cooling system cleaner such as Fleetguard

RESTORE

and RESTORE PLUS

. Follow

manufacturer’s directions on label.

Fleetguard is a trademark of Cummins Engine Company, Inc.
RESTORE is a trademark of Fleetguard.
RESTORE PLUS is a trademark of Fleetguard.

40-5

110306

PN=98

Continued on next page