Lubrication & maint./2000 hour/24 month, Section 40 – PowerTec OMRG25204 User Manual

Page 94

Advertising
background image

Lubrication & Maint./2000 Hour/24 Month

RG,RG34710,5583

–19–28JAN02–1/3

Adjusting Variable Speed (Droop) on
Generator Set Engines

RG12066

–UN–29JAN02

Droop Adjustment Screw

A—Adjustment Screw
B—Fast Idle Adjustment
C—Slow Idle Adjustment

Stanadyne Mechanical Injection Pumps Only

1. Warm engine to normal operating temperature.

2. When necessary, disconnect throttle linkage or cable.

3. Adjust slow idle (C) and adjust fast idle (B) speed

when necessary.

4. Run engine at fast idle, then apply load until reaching

rated speed.

5. Check power. Adjust with the screw (A) if needed.

6. Remove load from engine.

7. Again check and adjust fast idle if screw (A) has been

turned.

8. Repeat procedure until both the engine power and the

fast idle speed are correct.

9. Reinstall throttle linkage if previously removed.

Continued on next page

40-1

110306

PN=94