Checking air intake system – PowerTec OMRG25204 User Manual

Page 82

Advertising
background image

Lubrication & Maintenance/500 Hour/12 Month

RG,RG34710,5575

–19–07JAN02–1/1

Checking Air Intake System

RG4689

–UN–20DEC88

Check Clamps

RG7332B

–UN–22JAN99

Unloader Valve and Air Restriction Indicator

A—Clamps
B—Dust Unloader Valve
C—Air Restriction Indicator

IMPORTANT: The air intake system must not leak.

Any leak, no matter how small, may
result in internal engine damage due to
abrasive dirt and dust entering the
intake system.

1. Inspect all intake hoses (piping) for cracks. Replace as

necessary.

2. Check clamps (A) on piping which connect the air

cleaner, engine and, if present, turbocharger. Tighten
clamps as necessary. This will help prevent dirt from
entering the air intake system through loose
connections causing internal engine damage.

3. If engine has a rubber dust unloader valve (B), inspect

the valve on bottom of air cleaner for cracks or
plugging. Replace as necessary.

IMPORTANT: ALWAYS REPLACE primary air cleaner

element when air restriction indicator
shows a vacuum of 625 mm (25 in.)
H

2

O, is torn, or visibly dirty.

4. Test air restriction indicator (C) for proper operation.

Replace indicator as necessary.

IMPORTANT: If not equipped with air restriction

indicator, replace air cleaner elements
at 500 Hours or 12 Months, whichever
occurs first.

35-2

110306

PN=82