Specifications – PowerTec OMRG25204 User Manual

Page 138

Advertising
background image

Specifications

OURGP11,000001D

–19–13OCT06–1/9

Engine Power Ratings And Fuel Injection Pump Specifications

NOTE: The power specifications shown below apply to

Dubuque, Torreon and Saran-built OEM
engines. Specifications are subject to change.
Refer to factory DTAC for assistance.

Engine speeds listed are as preset to factory
specification. In most cases, slow idle speed
will be reset depending upon specific vehicle
application requirements. Refer to your

machine technical manual for engine speeds
that are different from those preset at the
factory.

Power ratings specify flywheel power for a
bare engine without the drag effect of a
cooling fan or other accessories like an air
compressor.

POWER RATINGS ON DYNAMOMETER FOR OEM ENGINES

Injection

Original

Replaced

Pump

Injection

By Injection

Rated

No Load

Power

Option

Pump (Part

Pump (Part

Governor

Speed (rpm)

Slow Idle

Fast Idle

Rating

Engine Model

Code

No.)

No.)

Regulation

At Full Load

(rpm)

(rpm)

kW (HP)

4045DF120

16MR

RE504463

STD

2500

850

2700

63 (85)

16MS

RE504464

STD

2500

850

2700

63 (85)

165F

RE503729

3—5%

1500

1560

44 (59)

165G

RE504693

3—5%

1500

1560

44 (59)

16RB

RE503729

3—5%

1500

1560

44 (59)

16RC

RE504693

3—5%

1500

1560

44 (59)

16ZW

RE509527

3—5%

2500

850

2700

63 (85)

16ZX

RE509528

3—5%

2500

850

2700

63 (85)

16ZY

RE509529

3—5%

2500

850

2700

63 (85)

4045DF150

1601

RE61649

RE67557

STD

2500

850

2700

60 (80)

1601

RE67557

STD

2500

850

2700

60 (80)

1602

RE59809

STD

2500

850

2700

63 (85)

1603

RE63555

RE67558

3—5%

1800

1150

1870

53 (71)

1603

RE67558

RE505070

3—5%

1800

1150

1870

53 (71)

1603

RE505070

RE506132

3—5%

1800

1150

1870

53 (71)

1603

RE506132

3—5%

1800

1150

1870

53 (71)

1663

RE71089

RE500949

STD

2500

1600

2700

60 (80)

1663

RE500949

STD

2500

1600

2700

60 (80)

1671

RE67559

RE502714

STD

2500

850

2700

60 (80)

1671

RE502714

STD

2500

850

2700

60 (80)

1673

RE60085

RE67560

3—5%

1800

1400

1870

53 (71)

1673

RE67560

RE506130

3—5%

1800

1400

1870

53 (71)

1673

RE506130

3—5%

1800

1400

1870

53 (71)

1674

RE60089

RE67561

3—5%

1800

1400

1870

53 (71)

1674

RE67561

RE506131

3—5%

1800

1400

1870

53 (71)

1674

RE506131

3—5%

1800

1400

1870

53 (71)

1691

RE61649

RE500831

STD

2500

850

2700

60 (80)

1691

RE500831

RE500948

STD

2500

850

2700

60 (80)

1691

RE500948

STD

2500

850

2700

60 (80)

16BG

RE69778

RE502712

STD

2500

850

2700

63 (85)

16BG

RE502712

STD

2500

850

2700

63 (85)

60-3

110306

PN=138

Continued on next page

Advertising